Testing & QC
Slump Test (IS 1199)
// Definition
A standard field test measuring the consistency of fresh concrete using a 300 mm slump cone. The collapse height after lifting the cone is the slump value.
Procedure: fill cone in three layers, rod each layer 25 times, lift vertically, measure subsidence. Acceptance tolerance: ±25 mm of target.
// Related Indian Standards
IS 1199IS 456
// Cross-references
Was this helpful?