About this code
Standard test methods for hardened concrete — cube and cylinder compressive strength, flexural strength, splitting tensile strength.
Key sections
- 01Cube compressive strength
- 02Cylinder strength
- 03Flexural strength
- 04Splitting tensile
- 05Sampling and curing
Critical clauses
150mm cubes, 28-day water cure, loaded at 14 N/mm2/min.
In practiceMost common QC test in India.
Read with IS 456 clause 16.
In practiceMean of 4 >= fck + 0.825σ.
100x100x500 prism, 4-point load.
In practiceUsed for pavements and PQC.
Practical implications
Specify cube count per IS 456.
Calibrated CTM mandatory.
Cast cubes from each pour, mark properly.
FAQs
Cylinder ~ 0.8 × cube. India uses cubes; US uses cylinders.
Purchase the official Bureau of Indian Standards publication for the complete, legally-binding text.
Open BIS Portal