Skip to content
    Back to library
    Testing Standards

    IS 516 (Part 1):2021

    Hardened Concrete - Methods of Test

    Edition: Latest RevisionYear: 2021Pages: 50

    About this code

    Standard test methods for hardened concrete — cube and cylinder compressive strength, flexural strength, splitting tensile strength.

    Key sections

    1. 01Cube compressive strength
    2. 02Cylinder strength
    3. 03Flexural strength
    4. 04Splitting tensile
    5. 05Sampling and curing

    Critical clauses

    Clause 5.0Cube Test Procedure

    150mm cubes, 28-day water cure, loaded at 14 N/mm2/min.

    In practiceMost common QC test in India.

    Clause 5.5Acceptance

    Read with IS 456 clause 16.

    In practiceMean of 4 >= fck + 0.825σ.

    Clause 6.0Flexural Test

    100x100x500 prism, 4-point load.

    In practiceUsed for pavements and PQC.

    Practical implications

    For specifiers

    Specify cube count per IS 456.

    For suppliers

    Calibrated CTM mandatory.

    For executors

    Cast cubes from each pour, mark properly.

    FAQs

    Cube vs cylinder strength?

    Cylinder ~ 0.8 × cube. India uses cubes; US uses cylinders.

    // Need full code text?

    Purchase the official Bureau of Indian Standards publication for the complete, legally-binding text.

    Open BIS Portal

    This summary is for quick reference. For legal compliance and project specification, refer to the official BIS publication. Standards are periodically updated; verify current edition with BIS before reliance.

    // Your privacy

    We use cookies to make this site work better.

    Essential cookies are always on. Analytics and marketing cookies are off by default — turn them on if you'd like to help us improve. See our Cookie Policy and Privacy Policy.