    IS 12330:1988

    Sulphate Resisting Portland Cement

    Edition: 1st EditionYear: 1988Pages: 12

    About this code

    Specification for SRC with low C3A content (<5%) for use in sulphate-rich environments — coastal soils, sewage works, industrial floors.

    Key sections

    1. 01Scope
    2. 02Chemical limits (C3A < 5%)
    3. 03Physical requirements
    4. 04Testing

    Critical clauses

    Clause 5.1C3A Limit

    Tricalcium aluminate <= 5%.

    In practiceCritical for sulphate resistance.

    Clause 6.0Strength

    Comparable to OPC 33-43.

    In practiceUse only where sulphate exposure is verified.

    Practical implications

    For specifiers

    Test soil sulphate before specifying.

    For suppliers

    Made-to-order in most markets.

    For executors

    Same handling as OPC.

    FAQs

    When is SRC required?

    When sulphate in soil > 0.2% or in groundwater > 300 mg/L.

    // Need full code text?

    Purchase the official Bureau of Indian Standards publication for the complete, legally-binding text.

    Open BIS Portal

    This summary is for quick reference. For legal compliance and project specification, refer to the official BIS publication. Standards are periodically updated; verify current edition with BIS before reliance.